Effect of Unloading Knee Brace on Dynamic Parameters of the Stance Phase of Gait in Patients with Knee Osteoarthritis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F18%3AA20020P3" target="_blank" >RIV/61988987:17110/18:A20020P3 - isvavai.cz</a>
Result on the web
<a href="https://europepmc.org/abstract/med/30257780" target="_blank" >https://europepmc.org/abstract/med/30257780</a>
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Effect of Unloading Knee Brace on Dynamic Parameters of the Stance Phase of Gait in Patients with Knee Osteoarthritis
Original language description
PURPOSE OF THE STUDY Knee joint is the most common place where osteoarthritis may occur. A specific therapy is indicated to patients depending on the degree of disability and other signs. The available methods and their clinical value are regularly assessed in systematic reviews and meta-analysis of clinical studies. The evidence of working mechanism of the specific therapeutic intervention is another important part of evaluating its therapy effect. One of the possibilities of knee osteoarthritis conservative treatment is a functional prophylactic knee brace. This type of knee brace is designed to transfer the load away from the affected part of the knee joint in every step. The main goal of this study was to determine the effect of a prophylactic knee brace on dynamic parameters of the stance phase of gait in patients with knee osteoarthritis. MATERIAL AND METHODS The research involved twelve subjects with predominantly unilateral medial knee osteoarthritis of grade 2 and 3. Six patients did not complete the study. Therefore, the data of six persons were processed (average age 68.3 ± 4.4 years, average weight 83 ± 15.9 kg, average height 170.5 ± 11.7 cm). There were two piezoelectric Kistler 9286AA force plates used to determine the reaction forces. In total, six attempts were evaluated - three attempts with the knee brace and three attempts without it. Each subject completed three measurements. The first one took place at the beginning of the research, the second one after three months of using the brace, and the last one took place three months after the brace removal. The data processing methods were accustomed. At the beginning and at the end of the study the patients completed the WOMAC questionnaire and determined the level of their pain on the visual analogue scale (VAS). RESULTS The minimum value (p = 0.020) and the second maximum value (p = 0.035) of vertical reaction force significantly increased on the unaffected limb after a short-term application of a
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30211 - Orthopaedics
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2018
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
CTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA
ISSN
0001-5415
e-ISSN
—
Volume of the periodical
85
Issue of the periodical within the volume
3
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
4
Pages from-to
204-208
UT code for WoS article
000436528700007
EID of the result in the Scopus database
—