Measuring respiratory and heart rate using a fiber optic interferometer: A pilot study in a neonate model
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F22%3AA2402NLD" target="_blank" >RIV/61988987:17110/22:A2402NLD - isvavai.cz</a>
Alternative codes found
RIV/61989100:27240/22:10251222 RIV/00179906:_____/22:10454370 RIV/00843989:_____/22:E0109997
Result on the web
<a href="https://www.webofscience.com/wos/woscc/full-record/WOS:000899665600001" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:000899665600001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3389/fped.2022.957835" target="_blank" >10.3389/fped.2022.957835</a>
Alternative languages
Result language
angličtina
Original language name
Measuring respiratory and heart rate using a fiber optic interferometer: A pilot study in a neonate model
Original language description
IntroductionThe study aim was to test the safety and efficacy of a pad with optic fibers developed for monitoring newborn respiratory rate (RR) and heart rate (HR). MethodsThirty New Zealand White rabbits were included, divided by weight into three groups. RR and HR were measured using two methods for each rabbit: ECG electrodes as the reference method and a newly developed pad with an experimental fiber optic system (EFOS) as the experimental method. ResultsAnalysis was performed on data for 29 rabbits (10 female, 34%; 19 male, 66%). EFOS performed better at measuring RR compared with HR. RR values did not differ significantly between the methods for the whole group (p = 0.151) or within each sex (female: p > 0.999; male: p = 0.075). Values for HR, however, did differ between methods for the whole group of animals (p < 0.001) and also within groups by sex (female: p < 0.001; male: p = 0.006). ConclusionThe results of this preclinical study demonstrate the potential of this non-invasive method using a fiber optic pad to measure HR and RR.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30209 - Paediatrics
Result continuities
Project
<a href="/en/project/EE2.3.20.0217" target="_blank" >EE2.3.20.0217: The Development of Excellence of the Telecommunication Research Team in Relation to International Cooperation</a><br>
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
FRONTIERS IN PEDIATRICS
ISSN
2296-2360
e-ISSN
—
Volume of the periodical
—
Issue of the periodical within the volume
prosinec 2022
Country of publishing house
CH - SWITZERLAND
Number of pages
8
Pages from-to
—
UT code for WoS article
000899665600001