Transnasal Endoscopic Pituitary Surgery-The Role of a CT Scan in Individual Tailoring of Posterior Septum Size Resection
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61988987%3A17110%2F23%3AA2402N7V" target="_blank" >RIV/61988987:17110/23:A2402N7V - isvavai.cz</a>
Result on the web
<a href="https://www.webofscience.com/wos/woscc/full-record/WOS:001130863100001" target="_blank" >https://www.webofscience.com/wos/woscc/full-record/WOS:001130863100001</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/tomography9060172" target="_blank" >10.3390/tomography9060172</a>
Alternative languages
Result language
angličtina
Original language name
Transnasal Endoscopic Pituitary Surgery-The Role of a CT Scan in Individual Tailoring of Posterior Septum Size Resection
Original language description
Objective: This study was designed to evaluate the possibility of predicting the minimum size of septal resection for safe tumor extraction in transnasal paraseptal pituitary adenoma resection from preoperative computed tomography scans. Methods: A retrospective CT scan analysis was performed on 20 patients who underwent endoscopic pituitary surgery at the University Hospital in Ostrava. Virtual insertion of the straight instrument into the sphenoid cavity was simulated using a CT scan. The minimum septal resection size was predicted and compared to various diameters in the nasal cavity. The results were then compared with cadaveric dissections, in which septal resections were performed at 1 cm and 2 cm distances from the anterior sphenoid wall. The association between cadaver dissections and CT scan results was studied. Results: A total of 20 patients who underwent endoscopic transnasal surgery for pituitary adenoma between the years 2020 and 2021 were enrolled in the study. The mean virtual posterior septal size resection needed to reach the medial edge of the ICA with the straight instrument, without infracturing the nasal septum, was 13.2 mm. In cadavers with a 1 cm posterior septal resection, the medial edge of the ICA was reached with the straight instrument. In 2 cm resections, it was possible to reach beyond the lateral edge of the ICA. Conclusion: There is no significant correlation between the minimum septal size resection and measured diameters in the nasal cavity. According to our study, a 1 cm resection is sufficient for a non-extended pituitary tumor extraction. More extensive septal resections allow for better maneuverability and overview in the surgical field.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30224 - Radiology, nuclear medicine and medical imaging
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
TOMOGRAPHY
ISSN
2379-1381
e-ISSN
2379-139X
Volume of the periodical
—
Issue of the periodical within the volume
6
Country of publishing house
CH - SWITZERLAND
Number of pages
11
Pages from-to
2222-2232
UT code for WoS article
001130863100001
EID of the result in the Scopus database
2-s2.0-85180690068