Analysis of the Fire Properties of Blown Insulation from Crushed Straw in the Buildings

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F21%3A10249016" target="_blank" >RIV/61989100:27120/21:10249016 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.mdpi.com/1996-1944/14/15/4336" target="_blank" >https://www.mdpi.com/1996-1944/14/15/4336</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/ma14154336" target="_blank" >10.3390/ma14154336</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Analysis of the Fire Properties of Blown Insulation from Crushed Straw in the Buildings

  • Original language description

    Sustainable development in civil engineering is the clear and necessary goal of the current generation. There are many possibilities for reducing the use of depletable resources. One of them is to use renewable and recyclable materials on a larger scale in the construction industry. One possibility is the application of natural thermal insulators. A typical example is a crushed straw, which is generated as agricultural waste in the Czech Republic. Due to its small dimensions and good thermal insulation parameters, this material can also be used as blown thermal insulation. The research aims to examine the fire resistance of crushed straw as blown insulation. The single-flame source fire test results, thermal attack by a single burning item (SBI) test and large-scale test of a perimeter wall segment are shown. The results show that blown insulation made of crushed straw meets the requirements of fire protection. In addition, crushed straw can be also used to protect load-bearing structures due to its behaviour. This article also shows the production process of crushed straw used as blown insulation in brief.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20100 - Civil engineering

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Materials

  • ISSN

    1996-1944

  • e-ISSN

  • Volume of the periodical

    14

  • Issue of the periodical within the volume

    15

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    12

  • Pages from-to

    4336

  • UT code for WoS article

    000682042900001