All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Physical Tests of Alternative Connections of Different High Roof Purlins Regarding Upward Loading

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F21%3A10249327" target="_blank" >RIV/61989100:27120/21:10249327 - isvavai.cz</a>

  • Result on the web

    <a href="https://www.mdpi.com/2075-5309/11/11/512" target="_blank" >https://www.mdpi.com/2075-5309/11/11/512</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/buildings11110512" target="_blank" >10.3390/buildings11110512</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Physical Tests of Alternative Connections of Different High Roof Purlins Regarding Upward Loading

  • Original language description

    Thin-walled cold-rolled sections are used in the construction industry, especially in the roofing of large-span halls. The load-bearing capacity of a thin-walled structure depends to a large extent on the load-bearing capacity of the details at the point of attachment to the structure and the interconnection of the individual thin-walled elements. Therefore, in the case of thin-walled structures, it is necessary to use additional structural elements such as local reinforcement, stabilising elements, supports, and other structural measures such as the doubling of profiles. This paper focused on the behaviour of tall Z300 and Z350 mm thin-walled trusses at the connection to the superstructure regarding upward loading (e.g., wind suction and so on). Two section thicknesses, 1.89 mm and 2.85 mm, were experimentally analysed. Furthermore, two types of connections were prepared, more precisely without and with a reinforced buckle. The experiments aimed to investigate the behaviour and load-carrying capacity of the detail of the roof truss connections to the supporting structure. The resulting load capacity values were compared with normative approaches. Analyses of the details of the bolt in the connection are also presented. The paper presents a practical evaluation of the physical test on real structural members.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20102 - Construction engineering, Municipal and structural engineering

Result continuities

  • Project

  • Continuities

    V - Vyzkumna aktivita podporovana z jinych verejnych zdroju

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Buildings

  • ISSN

    2075-5309

  • e-ISSN

  • Volume of the periodical

    11

  • Issue of the periodical within the volume

    11

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    11

  • Pages from-to

  • UT code for WoS article

    000727283700001

  • EID of the result in the Scopus database