New Calculation Technique for Assessment of Smoke Layer Interface in Large Buildings in Connection with the Design of Buildings in the Czech Republic
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27120%2F22%3A10250022" target="_blank" >RIV/61989100:27120/22:10250022 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27200/22:10250022
Result on the web
<a href="https://www.mdpi.com/2071-1050/14/11/6445" target="_blank" >https://www.mdpi.com/2071-1050/14/11/6445</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/su14116445" target="_blank" >10.3390/su14116445</a>
Alternative languages
Result language
angličtina
Original language name
New Calculation Technique for Assessment of Smoke Layer Interface in Large Buildings in Connection with the Design of Buildings in the Czech Republic
Original language description
The sustainability of the indoor environment of buildings is also related to the conditions that arise in the case of fires. Fires in buildings are characterized by the formation of combustion products, which can significantly endanger the life and health of people. One of the major sources of danger is smoke. If there is no smoke exhaust into the outside environment during the development of the fire, the building is gradually filled with smoke. The important characteristic of the smoke layer is the level of the smoke layer, which changes over time. Several methods have been derived for determining the descent of the smoke layer in an enclosed area of space, which mainly differ in terms of the application area and limits of use. The methods used in the Czech Republic for the assessment of smoke layer descent in the case of fires do not have a clear rationale and in many cases lead to completely misleading results. For this reason, in connection with the standards for the assessment of the buildings in the Czech Republic, a new calculation technique (CSN) has been derived, which has been compared with the selected simple calculation techniques in large buildings. The deviations between the results have been evaluated by the percentage bias method (PBIAS), while the largest deviation, compared to the ISO standard technique, did not exceed 20%. The CSN calculation technique shows a favourable compliance with the technique presented by the ISO standard, where the deviation did not exceed 1.6%. In response to the proposed standards in the Czech Republic, the CSN calculation technique enables the assessment of safe evacuation in relation to the smoke layer interface and can be a considered perspective.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
50901 - Other social sciences
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
SUSTAINABILITY
ISSN
2071-1050
e-ISSN
2071-1050
Volume of the periodical
14
Issue of the periodical within the volume
11
Country of publishing house
CH - SWITZERLAND
Number of pages
18
Pages from-to
1-18
UT code for WoS article
000809140300001
EID of the result in the Scopus database
2-s2.0-85131556159