Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F21%3A10247725" target="_blank" >RIV/61989100:27240/21:10247725 - isvavai.cz</a>
Alternative codes found
RIV/62156489:43110/21:43919983 RIV/62156489:43210/21:43919983
Result on the web
<a href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253427" target="_blank" >https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0253427</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0253427" target="_blank" >10.1371/journal.pone.0253427</a>
Alternative languages
Result language
angličtina
Original language name
Parameters setting of Frequency Converter PI regulation to ensure the vacuum of the milking process
Original language description
This paper presents regulation of an asynchronous induction motor so as to create a stable vacuum milk pump using Variable Frequency Drive (VFD). Contribution includes providing information about the usage of the VFD, which regulates the activity of an asynchronous induction motor so that the vacuum pump milking machine creates stable vacuum. The paper describes the functional and time dependence of input values and output parameters of frequency converters at changing electric motor speed. For simulation and verification the milking process a mathematical model of the milking machine was created. The simulation was verified in Matlab/Simulink software. The constructed mathematical model showed symmetric regulation. Control model symmetry was verified at the laboratory of milking machine. The possibility to remove the control valve from milking equipment was proven using the measured data. It was found that constant vacuum values can be maintained. A constant vacuum can be maintained by changing vacuum pump speed. This control is of an accepted standard (ISO 5707: 2007). The power saving control values (on the milking equipment) of the VFD were positive throughout the measuring range. The performance of the milking vacuum pump is normally designed from the maximum air consumption of the milking machine at nominal vacuum (50 kPa), and a performance reserve is added to this. This means that the pump is operated between the ranges 7.53 and 15.06 dm(3) s(-1). By using a vacuum pump controlled by a VFD, power savings can be achieved from 32.50% to 54.02% compared to a control valve.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/EF16_019%2F0000867" target="_blank" >EF16_019/0000867: Research Centre of Advanced Mechatronic Systems</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PLoS One
ISSN
1932-6203
e-ISSN
—
Volume of the periodical
16
Issue of the periodical within the volume
7
Country of publishing house
US - UNITED STATES
Number of pages
17
Pages from-to
—
UT code for WoS article
000668791400071