Analysis of the Dual Active Bridge-Based DC-DC Converter Topologies, High-Frequency Transformer, and Control Techniques
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F22%3A10251064" target="_blank" >RIV/61989100:27240/22:10251064 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27730/22:10251064
Result on the web
<a href="https://www.mdpi.com/1996-1073/15/23/8944/htm" target="_blank" >https://www.mdpi.com/1996-1073/15/23/8944/htm</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/en15238944" target="_blank" >10.3390/en15238944</a>
Alternative languages
Result language
angličtina
Original language name
Analysis of the Dual Active Bridge-Based DC-DC Converter Topologies, High-Frequency Transformer, and Control Techniques
Original language description
A power conversion system needs high efficiency for modern-day applications. A DC-DC isolated bidirectional dual active bridge-based converter promises high efficiency and reliability. There are several converter topologies available in the market claiming to be the best of their type, so it is essential to choose from them based on the best possible result for operation in a variety of applications. As a result, this article examines the characteristics, functionality, and benefits of dual active bridge-based DC-DC converter topologies and the other members of the family, as well as their limits and future advances. A high-frequency transformer is also an important device that is popular due to high leakage inductance in dual active bridge (DAB) converters. Therefore, a detailed review is presented, and after critical analysis, minimized leakage inductance in the toroidal transformer is obtained using the ANSYS Maxwell platform. Furthermore, this work includes a comprehensive examination of the control approaches for DAB converters, which is important for selecting the most appropriate technique for a certain application. The outcome of ANSYS Maxwell is integrated with a DAB-based boost inverter in the MATLAB/Simulink environment, and the results are validated with the help of an experimental prototype.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
<a href="/en/project/TN01000007" target="_blank" >TN01000007: National Centre for Energy</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2022
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energies
ISSN
1996-1073
e-ISSN
—
Volume of the periodical
15
Issue of the periodical within the volume
23
Country of publishing house
CH - SWITZERLAND
Number of pages
23
Pages from-to
nestrankovano
UT code for WoS article
000897297500001
EID of the result in the Scopus database
2-s2.0-85143792369