Independent component analysis algorithms for non-invasive fetal electrocardiography
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F23%3A10252576" target="_blank" >RIV/61989100:27240/23:10252576 - isvavai.cz</a>
Result on the web
<a href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0286858" target="_blank" >https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0286858</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0286858" target="_blank" >10.1371/journal.pone.0286858</a>
Alternative languages
Result language
angličtina
Original language name
Independent component analysis algorithms for non-invasive fetal electrocardiography
Original language description
The independent component analysis (ICA) based methods are among the most prevalent techniques used for non-invasive fetal electrocardiogram (NI-fECG) processing. Often, these methods are combined with other methods, such adaptive algorithms. However, there are many variants of the ICA methods and it is not clear which one is the most suitable for this task. The goal of this study is to test and objectively evaluate 11 variants of ICA methods combined with an adaptive fast transversal filter (FTF) for the purpose of extracting the NI-fECG. The methods were tested on two datasets, Labour dataset and Pregnancy dataset, which contained real records obtained during clinical practice. The efficiency of the methods was evaluated from the perspective of determining the accuracy of detection of QRS complexes through the parameters of accuracy (ACC), sensitivity (SE), positive predictive value (PPV), and harmonic mean between SE and PPV (F1). The best results were achieved with a combination of FastICA and FTF, which yielded mean values of ACC = 83.72%, SE = 92.13%, PPV = 90.16%, and F1 = 91.14%. Time of calculation was also taken into consideration in the methods. Although FastICA was ranked to be the sixth fastest with its mean computation time of 0.452 s, it had the best ratio of performance and speed. The combination of FastICA and adaptive FTF filter turned out to be very promising. In addition, such device would require signals acquired from the abdominal area only; no need to acquire reference signal from the mother's chest. Copyright: (C) 2023 Jaros et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20201 - Electrical and electronic engineering
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PLoS One
ISSN
1932-6203
e-ISSN
—
Volume of the periodical
18
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
31
Pages from-to
"e0286858@@@###"
UT code for WoS article
001004606500017
EID of the result in the Scopus database
2-s2.0-85161200114