Hybrid optimal-FOPID based UPQC for reducing harmonics and compensate load power in renewable energy sources grid connected system
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27240%2F24%3A10255315" target="_blank" >RIV/61989100:27240/24:10255315 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27730/24:10255315
Result on the web
<a href="https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0300145" target="_blank" >https://journals.plos.org/plosone/article?id=10.1371/journal.pone.0300145</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1371/journal.pone.0300145" target="_blank" >10.1371/journal.pone.0300145</a>
Alternative languages
Result language
angličtina
Original language name
Hybrid optimal-FOPID based UPQC for reducing harmonics and compensate load power in renewable energy sources grid connected system
Original language description
Integration of renewable energy sources (RES) to the grid in today's electrical system is being encouraged to meet the increase in demand of electrical power and also overcome the environmental related problems by reducing the usage of fossil fuels. Power Quality (PQ) is a critical problem that could have an effect on utilities and consumers. PQ issues in the modern electric power system were turned on by a linkage of RES, smart grid technologies and widespread usage of power electronics equipment. Unified Power Quality Conditioner (UPQC) is widely employed for solving issues with the distribution grid caused by anomalous voltage, current, or frequency. To enhance UPQC performance, Fractional Order Proportional Integral Derivative (FOPID) is developed; nevertheless, a number of tuning parameters restricts its performance. The best solution for the FOPID controller problem is found by using a Coati Optimization Algorithm (COA) and Osprey Optimization Algorithm (OOA) are combined to make a hybrid optimization CO-OA algorithm approach to mitigate these problems. This paper proposes an improved FOPID controller to reduce PQ problems while taking load power into account. In the suggested model, a RES is connected to the grid system to supply the necessary load demand during the PQ problems period. Through the use of an enhanced FOPID controller, both current and voltage PQ concerns are separately modified. The pulse signal of UPQC was done using the optimal controller, which analyzes the error value of reference value and actual value to generate pulses. The integrated design mitigates PQ issues in a system at non-linear load and linear load conditions. The proposed model provides THD of 12.15% and 0.82% at the sag period, 10.18% and 0.48% at the swell period, and 10.07% and 1.01% at the interruption period of non-linear load condition. A comparison between the FOPID controller and the traditional PI controller was additionally taken. The results showed that the recommended improved FOPID controller for UPQC has been successful in reducing the PQ challenges in the grid-connected RESs system.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20200 - Electrical engineering, Electronic engineering, Information engineering
Result continuities
Project
<a href="/en/project/TN02000025" target="_blank" >TN02000025: National Centre for Energy II</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2024
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
PLoS One
ISSN
1932-6203
e-ISSN
—
Volume of the periodical
19
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
53
Pages from-to
nestránkováno
UT code for WoS article
001222537900018
EID of the result in the Scopus database
2-s2.0-85193207350