Impact of a Redox Flow Battery on the Frequency Stability of a Five-Area System Integrated with Renewable Sources

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F23%3A10252768" target="_blank" >RIV/61989100:27730/23:10252768 - isvavai.cz</a>

  • Alternative codes found

    RIV/61989100:27240/23:10252768

  • Result on the web

    <a href="https://www.mdpi.com/1996-1073/16/14/5540" target="_blank" >https://www.mdpi.com/1996-1073/16/14/5540</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/en16145540" target="_blank" >10.3390/en16145540</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Impact of a Redox Flow Battery on the Frequency Stability of a Five-Area System Integrated with Renewable Sources

  • Original language description

    Energy storage devices are imperative to damp out the oscillations caused by sudden magnified disturbances occurring in a power system. The presence of a small rating of storage device in each area can alleviate the system oscillations effectively. Therefore, in this work, redox flow batteries (RFBs) have been integrated in each area of a five-area interconnected system for effective load frequency control (LFC). The RFB pumps up the active power into the system quickly to meet the short-time overload; in turn, the efficacy of the LFC in the system is boosted. Despite the presence of the RFB in the power system, a secondary controller is necessary to quench the deviation of frequency and tie-line power caused by the power mismatch between demand and generation. In this perspective, a cascade controller incorporated with a fractional operator (FO) has been endorsed and designed through a nascent selfish herd optimizer technique to evaluate the transient response of the system. Besides this, the unprecedented performance of fractional-order cascade controllers has been compared with one-stage classical controllers with and without a fractional operator. Further, the robustness of the proposed controller has been inspected through subjecting it to a random load in the presence/absence of an RFB and parametric variation. Finally, the proposed model has been simulated in the OPAL-RT-4510 platform to validate the performance of the proposed controller that has produced in the MATLAB environment.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20200 - Electrical engineering, Electronic engineering, Information engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2023

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Energies

  • ISSN

    1996-1073

  • e-ISSN

    1996-1073

  • Volume of the periodical

    16

  • Issue of the periodical within the volume

    14

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    29

  • Pages from-to

  • UT code for WoS article

    001036123000001

  • EID of the result in the Scopus database