Impact of a Redox Flow Battery on the Frequency Stability of a Five-Area System Integrated with Renewable Sources
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27730%2F23%3A10252768" target="_blank" >RIV/61989100:27730/23:10252768 - isvavai.cz</a>
Alternative codes found
RIV/61989100:27240/23:10252768
Result on the web
<a href="https://www.mdpi.com/1996-1073/16/14/5540" target="_blank" >https://www.mdpi.com/1996-1073/16/14/5540</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/en16145540" target="_blank" >10.3390/en16145540</a>
Alternative languages
Result language
angličtina
Original language name
Impact of a Redox Flow Battery on the Frequency Stability of a Five-Area System Integrated with Renewable Sources
Original language description
Energy storage devices are imperative to damp out the oscillations caused by sudden magnified disturbances occurring in a power system. The presence of a small rating of storage device in each area can alleviate the system oscillations effectively. Therefore, in this work, redox flow batteries (RFBs) have been integrated in each area of a five-area interconnected system for effective load frequency control (LFC). The RFB pumps up the active power into the system quickly to meet the short-time overload; in turn, the efficacy of the LFC in the system is boosted. Despite the presence of the RFB in the power system, a secondary controller is necessary to quench the deviation of frequency and tie-line power caused by the power mismatch between demand and generation. In this perspective, a cascade controller incorporated with a fractional operator (FO) has been endorsed and designed through a nascent selfish herd optimizer technique to evaluate the transient response of the system. Besides this, the unprecedented performance of fractional-order cascade controllers has been compared with one-stage classical controllers with and without a fractional operator. Further, the robustness of the proposed controller has been inspected through subjecting it to a random load in the presence/absence of an RFB and parametric variation. Finally, the proposed model has been simulated in the OPAL-RT-4510 platform to validate the performance of the proposed controller that has produced in the MATLAB environment.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
20200 - Electrical engineering, Electronic engineering, Information engineering
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Energies
ISSN
1996-1073
e-ISSN
1996-1073
Volume of the periodical
16
Issue of the periodical within the volume
14
Country of publishing house
CH - SWITZERLAND
Number of pages
29
Pages from-to
—
UT code for WoS article
001036123000001