Simplified Indirect Estimation of Pump Flow Discharge: An Example from Serbia

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989100%3A27740%2F21%3A10247587" target="_blank" >RIV/61989100:27740/21:10247587 - isvavai.cz</a>

  • Result on the web

    <a href="https://doi.org/10.3390/w13060796" target="_blank" >https://doi.org/10.3390/w13060796</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.3390/w13060796" target="_blank" >10.3390/w13060796</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Simplified Indirect Estimation of Pump Flow Discharge: An Example from Serbia

  • Original language description

    In the absence of a flowmeter or due to its inaccuracy, the flow rate at the discharge section of the pipeline following the observed pump can be roughly estimated if the pressure can be measured instead. To use the proposed procedure two main conditions should be achieved: (1) a manometer should be installed at the discharge pipeline between the pump and the flow regulation valve, and (2) the actual curve that relates pressure and flow for the observed pump unit should be known in advance. The described example is from Serbia, but it is of interest for any water pumping station with a submersible pump (installed in wells or tanks) where a limited number of adequate places for the measuring of flow are available (if any are available at all), but where the pressure at the discharge pipe of the observed pump can be measured. This simplified method can find applicability in installations in remote rural regions where limited resources are available. The results show that the calculated values of the flow obtained by the presented method deviate greatly in relation to the measured values provided by the portable ultrasonic flowmeter, up to 60% at one of the measuring points. However, in relation to the measured values provided by the permanently installed flowmeter the discrepancy is significantly lower (0.6-6.8%).

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    10300 - Physical sciences

Result continuities

  • Project

    <a href="/en/project/TK03020027" target="_blank" >TK03020027: CEET - Center of Energy and Environmental Technologies</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2021

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Water

  • ISSN

    2073-4441

  • e-ISSN

  • Volume of the periodical

    13

  • Issue of the periodical within the volume

    6

  • Country of publishing house

    CH - SWITZERLAND

  • Number of pages

    15

  • Pages from-to

  • UT code for WoS article

    000651984800001

  • EID of the result in the Scopus database

    2-s2.0-85102747454