Diagnostic accuracy of lymphoscintigraphy and radioguided sentinel lymph node biopsy in patients with malignant melanoma.
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F08%3A00007201" target="_blank" >RIV/61989592:15110/08:00007201 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Diagnostic accuracy of lymphoscintigraphy and radioguided sentinel lymph node biopsy in patients with malignant melanoma.
Original language description
Aim: The incidence of false negative sentinel lymph node (SLN) is less than 2% in case of a direct comparison of SLN status with histological findings in the remaining lymph nodes in the lymphatic basin. However, the published data show that the incidence of lymphatic metastases in the adjacent lymphatic basins detected during a subsequent clinical follow-up in patients with negative SLN biopsy (SLNB) varies in patients with malignant melanoma (MM) from 4% to 27%. The aim of this study was to evaluate the diagnostic accuracy of SLNB in MM. Methods: 167 consecutive patients with MM underwent lymphoscintigraphy and radioguided SLNB and subsequently were followed at the Dept. of Oncology. 2 patients were excluded from the study due to the local recurrences of MM with secondary lymph node metastases, therefore a total of 165 patients were studied. Localization of MMs: 90 trunk, 65 extremities, 10 head and neck. TNM staging: 48 pT1, 65 pT2, 31 pT3, 17 pT4, 4 pTiS. The mean follow-up time re
Czech name
Diagnostická přesnost lymfoscintigrafie a radiačně navigované biopsie sentinelové uzliny u pacientů s maligním melanomem
Czech description
Cíl: Incidence falešně negativních sentinelových lymfatických uzlin (SLN) je menší než 2% v případě přímého srovnání SLN a histologického nálezu.
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FD - Oncology and haematology
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2008
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
European Journal of Nuclear Medicine and Molecular Imaging
ISSN
1619-7070
e-ISSN
—
Volume of the periodical
35
Issue of the periodical within the volume
2
Country of publishing house
DE - GERMANY
Number of pages
1
Pages from-to
—
UT code for WoS article
—
EID of the result in the Scopus database
—