Risk of hospital-acquired Legionellosis from microbial contamination of potable water at a Bone Marrow Transplant Unit in a Czech University Hospital
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F14%3A33151698" target="_blank" >RIV/61989592:15110/14:33151698 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Risk of hospital-acquired Legionellosis from microbial contamination of potable water at a Bone Marrow Transplant Unit in a Czech University Hospital
Original language description
The investigated of the potable water treatment room and the sanitary facilities of patient boxes was held. The potable water treatment room had three collection points (ball valves), while in the sanitary facilities potable water was collected from thetap, shower, and the flush tank. A swab was taken from the inside wall of the toilet tank. The samples and swabs of the flush tank water were Legionella pneumophila sg 1 and sg 6A positive. Disinfection of flush tanks with chlorine agents was recommended.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FN - Epidemiology, infection diseases and clinical immunology
OECD FORD branch
—
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Water Chemistry and Technology
ISSN
1063-455X
e-ISSN
—
Volume of the periodical
36
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
247-251