Indoor Noise Loading in Residential Prefabricated Buildings
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F75081431%3A_____%2F17%3A00001183" target="_blank" >RIV/75081431:_____/17:00001183 - isvavai.cz</a>
Result on the web
<a href="http://iopscience.iop.org/article/10.1088/1757-899X/245/8/082028/pdf" target="_blank" >http://iopscience.iop.org/article/10.1088/1757-899X/245/8/082028/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/1757-899X/245/8/082028" target="_blank" >10.1088/1757-899X/245/8/082028</a>
Alternative languages
Result language
angličtina
Original language name
Indoor Noise Loading in Residential Prefabricated Buildings
Original language description
Quality on indoor environment is among others also defined by an acoustic comfort and noise emissions. The indoor noise loading in the residential prefabricated buildings is specific problem related to structural design of these buildings. Problems with noise level of sanitary systems are mostly associated with hydraulic shock such as water distribution and sewage drainage. Another very common cause of excessive noise is also flushing the toilet or water fall on enamelled steel (bath or shower). This paper aims to analyse the acoustic properties in the residential prefabricated buildings. Sanitary core of the assessed apartment is in original condition without any alterations. The sanitary core is based on a formica (high-pressure laminate). The study discusses the maximum sound levels in the three assessed rooms for the three different noise sources. The values of maximum noise level are measured for the corridor, bedroom and living room. Sources of noise are common activities relating to the operation of sanitary core - the toilet flush in the toilet, falling water from the shower in the bathroom and the water falling on the bottom of the kitchen sink in the kitchen. Other sources of noise are eliminated or minimized during the experiment. The digital sound level meter Testo 815 is used for measurements. The measured values of maximum sound level LA,max [dB] are adjusted by the correction coefficient. The obtained values are compared with the hygienic limits for day and night period. Night hygienic limit (30 dB) is exceeded in all the rooms for all noise sources. This limit is exceeded from 17 to 73%. The values in the bedroom and the living room meet the daily hygienic limit (40 dB). The daily limit is exceeded only in the corridor. The highest values of noise are identified for the toilet flushing.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
20101 - Civil engineering
Result continuities
Project
—
Continuities
V - Vyzkumna aktivita podporovana z jinych verejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 8 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017)
ISBN
—
ISSN
1757-8981
e-ISSN
—
Number of pages
6
Pages from-to
—
Publisher name
Institute of Physics Publishing
Place of publication
Spojené království
Event location
Praha (Česká republika)
Event date
Jun 12, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—