Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F16%3A33159300" target="_blank" >RIV/61989592:15110/16:33159300 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26210/16:PU118616
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S1751616116300674" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1751616116300674</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jmbbm.2016.04.003" target="_blank" >10.1016/j.jmbbm.2016.04.003</a>
Alternative languages
Result language
angličtina
Original language name
Lubrication within hip replacements - Implication for ceramic-on-hard bearing couples
Original language description
The objective of the present study is to clarify the lubrication processes within artificial joints considering the ceramic femoral heads focusing on the role of particular proteins. Two optical methods were employed; colorimetric interferometry and fluorescent microscopy. The experiments were conducted in ball-on-disc configuration, where the ball is made from ceramic (Sulox(TM), BIOLOX((R))delta) and the disc from optical glass. The measurements were realized under pure rolling, partial negative and partial positive sliding, to get a complex information about the protein film behaviour under various conditions. Moreover, two different speeds were investigated; 5.7 and 22 mm/s, respectively. The contact was lubricated by saline solutions containing albumin and γ-globulin in a ratio 2:1, while the total protein concentration was 10.5 mg/ml. Under pure rolling conditions, the film thickness gradually increases with time/rolling distance independently of material and rolling speed, while the dominant fluid constituent is albumin. In the case of negative sliding, the film formation is time/distance/speed dependent. At lower speed, both proteins contribute to film thickness; at higher speed, the effect of γ-globulin is not substantial. When the disc is faster, the character of film formation is similar to the metal component in the case of Sulox ceramic. Biolox ceramic shows a different behaviour, while for both materials, the contribution of γ-globulin increases with increasing speed. As most of the results can be well explained in terms of specific proteins, it can be concluded that the experimental approach is suitable for the investigation of protein film formation considering the ceramic materials.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JR - Other machinery industry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LQ1601" target="_blank" >LQ1601: CEITEC 2020</a><br>
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of the Mechanical Behavior of Biomedical Materials
ISSN
1751-6161
e-ISSN
—
Volume of the periodical
61
Issue of the periodical within the volume
AUG
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
13
Pages from-to
371-383
UT code for WoS article
000380080400035
EID of the result in the Scopus database
—