All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73603562" target="_blank" >RIV/61989592:15110/20:73603562 - isvavai.cz</a>

  • Alternative codes found

    RIV/00098892:_____/20:N0000185

  • Result on the web

    <a href="https://link.springer.com/article/10.1007/s10916-020-01614-6" target="_blank" >https://link.springer.com/article/10.1007/s10916-020-01614-6</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s10916-020-01614-6" target="_blank" >10.1007/s10916-020-01614-6</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests

  • Original language description

    Pneumatic tube transport systems (PTS) for delivery of patient samples to a hemostasis laboratory are often used to reduce turnaround time for vital analyses. PTS in our hospital has the ability to regulate the transport speed in the range of 3–6 m/s with acceleration control technology. We evaluated the effects of PTS transport for routine coagulation tests, platelet function tests and special global coagulation tests. Duplicate samples were collected from 29 patients and 40 healthy individuals. One sample was sent using PTS and the other was carried by personnel to the lab for determination of protrombin time, activated partial thromboplastin time, trombin time, fibrinogen, antitrombin and thrombin generation test. Platelet function was measured by means of a Apact 4004® analyzer using the inductors (ADP, Arachidonic acid and Epinephrine). Samples transported using PTS with normal transport speed 6 m/s does not affect basic coagulation tests (PT, aPTT, FIB, TT and AT), but TGT has significantly altered. The use of PTS with controlled acceleration regulated the increase in thrombin generation from 10% to 3%, which is not statistically signifiant. The use of PTS with controlled acceleration did not show a significant difference even with the highly sensitive method of platelet aggregation. We conclude that PTS with acceleration control with transport speed from 3 to 6 m/s does not affect to platelet activity as measured by LTA and also global coagulation test - TGT. The advantage of PTS transport is very rapid assessment laboratory testing. From the above validation study, it is clear that PTS should always be validated for specialized laboratory methods and appropriately adapted to specific transport conditions. © 2020, Springer Science+Business Media, LLC, part of Springer Nature.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    30205 - Hematology

Result continuities

  • Project

  • Continuities

    S - Specificky vyzkum na vysokych skolach<br>I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2020

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    JOURNAL OF MEDICAL SYSTEMS

  • ISSN

    0148-5598

  • e-ISSN

  • Volume of the periodical

    44

  • Issue of the periodical within the volume

    9

  • Country of publishing house

    US - UNITED STATES

  • Number of pages

    5

  • Pages from-to

    "'142(1)'"-"'142(5)'"

  • UT code for WoS article

    000550734000001

  • EID of the result in the Scopus database

    2-s2.0-85088314634