Long-term outcome of paroxysmal atrial fibrillation catheter ablation with and without pulmonary vein dormant conduction after adenosine challenge
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15110%2F20%3A73604447" target="_blank" >RIV/61989592:15110/20:73604447 - isvavai.cz</a>
Alternative codes found
RIV/00098892:_____/20:N0000119
Result on the web
<a href="https://biomed.papers.upol.cz/pdfs/bio/2020/02/05.pdf" target="_blank" >https://biomed.papers.upol.cz/pdfs/bio/2020/02/05.pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5507/bp.2019.005" target="_blank" >10.5507/bp.2019.005</a>
Alternative languages
Result language
angličtina
Original language name
Long-term outcome of paroxysmal atrial fibrillation catheter ablation with and without pulmonary vein dormant conduction after adenosine challenge
Original language description
Objectives. The prognostic significance of adenosine-mediated pulmonary vein (PV) dormant conduction is unclear. We prospectively followed patients with adenosine-mediated PV reconduction with a subsequent repeated ablation until there was no reconduction inducible with patients without reconduction after PV isolation. Method and Results. Consecutive patients (n=179) with paroxysmal atrial fibrillation (AF) without prior catheter ablation (CA) were enlisted in the study. We used a point-by-point CA and general anesthesia in all patients. Twenty minutes after PV isolation we administered adenosine in a dose sufficient to produce an atrioventricular block. If a dormant conduction was present (n=54) we performed additional ablation until there was no adenosine mediated reconduction inducible. During 36 months of follow-up, all patients were examined for eight 7-day ECG recordings. There was no difference in arrhythmia recurrence rate between patients with and without dormant conduction (29.6 vs. 24.8% at 12 months, P=0.500; 31.5 vs. 30.4% at 36 months, P=1.000), for any echocardiographic parameter or any parameter of the ablation procedure. Conclusion. The patients with dormant conduction after adenosine during catheter ablation of paroxysmal atrial fibrillation with complete elimination of the dormant conduction by additional extensive ablation have the same outcome in the long term as patients without a dormant conduction.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
30201 - Cardiac and Cardiovascular systems
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2020
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
BIOMEDICAL PAPERS-OLOMOUC
ISSN
1213-8118
e-ISSN
—
Volume of the periodical
164
Issue of the periodical within the volume
2
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
7
Pages from-to
147-153
UT code for WoS article
000542635800005
EID of the result in the Scopus database
2-s2.0-85086663640