Determination of selected biogenic amines in red wines by automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142148" target="_blank" >RIV/61989592:15310/12:33142148 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.jchromb.2012.07.018" target="_blank" >http://dx.doi.org/10.1016/j.jchromb.2012.07.018</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.jchromb.2012.07.018" target="_blank" >10.1016/j.jchromb.2012.07.018</a>
Alternative languages
Result language
angličtina
Original language name
Determination of selected biogenic amines in red wines by automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis
Original language description
A screening analytical method based on an automated on-line combination of capillary isotachophoresis-capillary zone electrophoresis (cITP-CZE) in hydrodynamically closed separation system, equipped with photometric detection at 280 nm. was developed fora routine determination of the selected biogenic amines, namely histamine, 2-phenylethylamine and tyramine, in red wines. The evaluated limits of detection (LODs) were 0.35 mg L-1 for histamine, 0.33 mg L-1 for 2-phenylethylamine and 0.37 mg L-1 for tyramine. The repeatability of the migration time and peak area for histamine were 1.1% and 2.6%, respectively, for 2-phenylethylamine 0.7% and 2.0%, respectively, and for tyramine 0.8% and 2.1%. respectively. The method recoveries were 92.1% for histamine,96.4% for 2-phenylethylamine and 95.5% for tyramine. The developed automated cITP-CZE-UV method was applied for the determination of histamine, 2-phenylethylamine and tyramine in seven red wine samples originating from Czech Republic.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CB - Analytical chemistry, separation
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/ED2.1.00%2F03.0058" target="_blank" >ED2.1.00/03.0058: Regional Centre of Advanced Technologies and Materials</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences
ISSN
1570-0232
e-ISSN
—
Volume of the periodical
904
Issue of the periodical within the volume
9
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
5
Pages from-to
135-139
UT code for WoS article
000308734400018