All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

On-line preconcentration of perfluorooctanoic acid and perfluorooctanesulfonic acid by nonaqueous capillary electrophoresis

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F12%3A33142191" target="_blank" >RIV/61989592:15310/12:33142191 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1002/elps.201100665" target="_blank" >http://dx.doi.org/10.1002/elps.201100665</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1002/elps.201100665" target="_blank" >10.1002/elps.201100665</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    On-line preconcentration of perfluorooctanoic acid and perfluorooctanesulfonic acid by nonaqueous capillary electrophoresis

  • Original language description

    Separation of major environmental pollutants as perfluorooctanoic acid (PFOA) and perfluorooctanesulfonic acid (PFOS) by capillary electrophoresis is reported for the first time. It is not possible to resolve the solutes in an aqueous media. However, theuse of methanol and acetonitrile as the background electrolyte (BGE) solvents allowed their rapid separation in an uncoated capillary. A major effort was put into BGE optimization in respect to both separation efficiency and detection for further on-line preconcentration. 5 mmol.L-1 naphthalene-1-sulfonic acid and 10 mmol.L-1 triethylamine dissolved in ACN/MeOH (50:50 v/v) provided best separation and detection conditions. Next, the large-volume sample stacking and the field-amplified sample injectionwere applied and compared. Large-volume sample stacking improved limits of detection (LODs) with regard to the standard injection by 69 times for PFOA and 143 times for PFOS with LODs of 280 and 230 nmol.L-1, respectively. Field-amplified

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)<br>Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Electrophoresis

  • ISSN

    0173-0835

  • e-ISSN

  • Volume of the periodical

    33

  • Issue of the periodical within the volume

    14

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    8

  • Pages from-to

    2159-2166

  • UT code for WoS article

    000306959400013

  • EID of the result in the Scopus database