The permselective layer prepared onto carbon and gold surfaces by electropolymerization of phenolic cyclopentenedione-nostotrebin 6
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F14%3A33146325" target="_blank" >RIV/61989592:15310/14:33146325 - isvavai.cz</a>
Alternative codes found
RIV/61388971:_____/14:00440802 RIV/61989592:15110/14:33146325 RIV/00216208:11160/14:10282227 RIV/60461373:22340/14:43897625
Result on the web
<a href="http://www.sciencedirect.com/science/article/pii/S1388248113004190" target="_blank" >http://www.sciencedirect.com/science/article/pii/S1388248113004190</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.elecom.2013.10.032" target="_blank" >10.1016/j.elecom.2013.10.032</a>
Alternative languages
Result language
angličtina
Original language name
The permselective layer prepared onto carbon and gold surfaces by electropolymerization of phenolic cyclopentenedione-nostotrebin 6
Original language description
In this study, we report that electrooxidation of phenolic cyclopentenedione, 2,2?-bis[4,5-bis(4-hydroxybenzyl)-2-(4-hydroxyphenyl)- cyclopent-4-ene-1,3-dione] results in the formation of nonconducting films which make uniform, defect-free and stable layers with permselective properties on gold and carbon surfaces. The electropolymerization process proceeds in neutral aqueous medium at potentials higher than + 0.6 V (vs. Ag/AgCl, 3 M KCl). The polymer prepared was characterized by electrochemical methods, quartz crystal microbalance, Fourier transform Raman and infrared spectroscopies, and scanning electron microscopy. The polymeric film can be used for electrode coating and thus preparation of an anti-interference barrier, for example, in dopamine microelectrode sensor construction. The results presented here are the first evidence for the preparation of phenolic cyclopentenedione-based functional film.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/FR-TI4%2F457" target="_blank" >FR-TI4/457: Fully-automated microdialysis system with implemented electrochemistry sensor for on-line monitoring of biologically active substances</a><br>
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Electrochemistry Communications
ISSN
1388-2481
e-ISSN
—
Volume of the periodical
38
Issue of the periodical within the volume
JAN
Country of publishing house
US - UNITED STATES
Number of pages
4
Pages from-to
53-56
UT code for WoS article
000331504300014
EID of the result in the Scopus database
—