Bottom-up measurement uncertainty evaluation for Cr(III) and Cr(VI) speciation in natural water by HPLC-ICP-MS
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F61989592%3A15310%2F25%3A73633550" target="_blank" >RIV/61989592:15310/25:73633550 - isvavai.cz</a>
Result on the web
<a href="https://www.sciencedirect.com/science/article/pii/S0026265X25005442" target="_blank" >https://www.sciencedirect.com/science/article/pii/S0026265X25005442</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.microc.2025.113190" target="_blank" >10.1016/j.microc.2025.113190</a>
Alternative languages
Result language
angličtina
Original language name
Bottom-up measurement uncertainty evaluation for Cr(III) and Cr(VI) speciation in natural water by HPLC-ICP-MS
Original language description
The monitoring of Cr(III) and Cr(VI) in natural waters is essential for the assessment of chromium-based levels that deteriorate the water quality and adversely affect aquatic biota. The evaluation of the uncertainty of this monitoring is crucial for the determination of their fitness for purpose and for the objective interpretation of the quantitative information. There is a great need for a detailed bottom-up evaluation of the uncertainty of Cr(III) and Cr(VI) measurements in natural waters by ion-exchange high-performance liquid chromatography inductively coupled plasma mass spectrometry. Detailed models of the uncertainty of sample dilution, calibrator preparation and sample signal interpolation in a weighted calibration curve are proposed. The models proved adequate from the metrological compatibility between reference and estimated concentrations of spiked river waters. Measurement of Cr(III) and Cr(VI) above 0.98 mu g L-1 and 0.5 mu g L-1 with relative expanded uncertainties as low as 4.0%, and 2.3%, respectively, can be achieved. For not diluted samples, calibrators' values and sample signal interpolation are responsible for between 14% and 82% or 18% and 85% of the uncertainty. The analysis of a certified reference material proved that the Cr(III)/Cr(VI) interconversion during analytical work is negligible. The developed measurement models were successfully applied to the analysis of river waters and groundwater collected in the Czech Republic. Only Cr(III) at the concentration levels around 1 mu g L-1 was detected in the river samples, whereas a toxic Cr(VI) was determined in groundwater. The proposed validated methodology and user-friendly spreadsheet for the detailed evaluation of measurement uncertainty can be generally applied to other speciation approaches, where the separation techniques are hyphenated with either organic or elemental mass spectrometry.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2025
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
MICROCHEMICAL JOURNAL
ISSN
0026-265X
e-ISSN
1095-9149
Volume of the periodical
212
Issue of the periodical within the volume
MAY
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
7
Pages from-to
"113190-1"-"113190-7"
UT code for WoS article
001441408600001
EID of the result in the Scopus database
2-s2.0-85219362080