Determination of flavonoids using of square wave voltammetry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F05%3A00007474" target="_blank" >RIV/62156489:43210/05:00007474 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Determination of flavonoids using of square wave voltammetry
Original language description
The possible relation of flavonoid compounds and tumour diseases has been recently published. On the other hand it is hard to say that the impact of flavonoids on tumour diseases treatment is positive or negative without epidemiological studies. That iswhy it is necessary to suggest a simple, low cost and sensitive technique for determination of these compounds in biological material. Electrochemical measurements were performed with AUTOLAB Analyser (EcoChemie, Netherlands) connected to VA-Stand 663 (Metrohm, Switzerland), using a standard cell with three electrodes. The working electrode was a carbon paste electrode. The reference electrode was an Ag/AgCl/3M KCl electrode and the auxiliary electrode was a graphite electrode. The supporting electrolyte was prepared by mixing buffer components. The measurements were performed using the following parameters: initial potential = 0.1 V, end potential = 1.2 V, pulse amplitude = 49.85 mV, step potential = 1.95 mV, and frequency = 180 Hz. Ph
Czech name
Stanovení flavonoidů pomocí SWV
Czech description
The possible relation of flavonoid compounds and tumour diseases has been recently published. On the other hand it is hard to say that the impact of flavonoids on tumour diseases treatment is positive or negative without epidemiological studies. That iswhy it is necessary to suggest a simple, low cost and sensitive technique for determination of these compounds in biological material. Electrochemical measurements were performed with AUTOLAB Analyser (EcoChemie, Netherlands) connected to VA-Stand 663 (Metrohm, Switzerland), using a standard cell with three electrodes. The working electrode was a carbon paste electrode. The reference electrode was an Ag/AgCl/3M KCl electrode and the auxiliary electrode was a graphite electrode. The supporting electrolyte was prepared by mixing buffer components. The measurements were performed using the following parameters: initial potential = 0.1 V, end potential = 1.2 V, pulse amplitude = 49.85 mV, step potential = 1.95 mV, and frequency = 180 Hz. Ph
Classification
Type
D - Article in proceedings
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/GP525%2F04%2FP132" target="_blank" >GP525/04/P132: Study of protection mechanisms for stress-induced by heavy metals</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Vitamins 2005 - Targeted Nutritional Therapy
ISBN
80-7194-748-2
ISSN
—
e-ISSN
—
Number of pages
2
Pages from-to
175-176
Publisher name
Univerzita Pardubice
Place of publication
Pardubice, Czech Republic
Event location
—
Event date
—
Type of event by nationality
—
UT code for WoS article
—