Automated assay of natural antioxidants potency using pipetting robot and spectrophotometry

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F12%3A00187243" target="_blank" >RIV/62156489:43210/12:00187243 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.2478/v10136-012-0006-y" target="_blank" >http://dx.doi.org/10.2478/v10136-012-0006-y</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.2478/v10136-012-0006-y" target="_blank" >10.2478/v10136-012-0006-y</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Automated assay of natural antioxidants potency using pipetting robot and spectrophotometry

  • Original language description

    We decided to study the fully automated assay of antioxidants using not only automated sample measurements but also automated processing of samples and application of reagents. The automated pipetting system epMotion 5075 and the automated spectrophotometer BS 400 were chosen for the assay purposes. Five methods were introduced for the automation: 2-diphenyl-1-picrylhydrazyl (DPPH) test, ferric reducing antioxidant power (FRAP) method, 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid (ABTS) based test, N,N-dimethyl-1,4-diaminobenzene (DMPD) based test and the free radicals method. Samples containing one of the four antioxidants (standard rutin, quercitrin, ferulic and gallic acid) in a range 1--1000 ug/ml were used throughout. All of the tested methods were found suitable for implementation in an automated assay. However, some of them, such as the ABTS test failed to assay all tested antioxidants. The coefficients of determination were also unequal. FRAP methods provided the most

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Journal of applied biomedicine

  • ISSN

    1214-021X

  • e-ISSN

  • Volume of the periodical

    10

  • Issue of the periodical within the volume

    3

  • Country of publishing house

    CZ - CZECH REPUBLIC

  • Number of pages

    13

  • Pages from-to

    155-167

  • UT code for WoS article

    304188400003

  • EID of the result in the Scopus database