Accuracy of the FT-NIR Method in Evaluating the Fat Content of Milk Using Calibration Models Developed for the Reference Methods According to Röse-Gottlieb and Gerber
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F16%3A43909541" target="_blank" >RIV/62156489:43210/16:43909541 - isvavai.cz</a>
Alternative codes found
RIV/70883521:28110/16:43874639
Result on the web
<a href="http://dx.doi.org/10.5740/jaoacint.16-0107" target="_blank" >http://dx.doi.org/10.5740/jaoacint.16-0107</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.5740/jaoacint.16-0107" target="_blank" >10.5740/jaoacint.16-0107</a>
Alternative languages
Result language
angličtina
Original language name
Accuracy of the FT-NIR Method in Evaluating the Fat Content of Milk Using Calibration Models Developed for the Reference Methods According to Röse-Gottlieb and Gerber
Original language description
The study examined the effect of the choice of reference method on the functionality and reliability of calibrations in near-IR (NIR) spectroscopy intended for measuring the fat content in raw cow's milk. The fat content in the milk samples was evaluated using methods according to either Röse-Gottlieb or Gerber. The same samples were then subjected to analysis on an Antaris FT-NIR spectrometer. Using a partial least-squares algorithm, calibration models were created for both methods from the values measured. The calibration models show very good values of standard error of calibration: 0.133 for the Gerber method and 0.095 for the Röse-Gottlieb method. These calibrations were subsequently used to analyze 30 new samples of cow's milk of undefined fat content, and the differences in the values were evaluated using statistical paired t-test to a median value at a probability level of α = 0.05. No statistically significant differences were found. It was revealed that the reference method used for calibrating the device evaluating the fat content in raw cow's milk has no effect on the functionality and reliability of the calibration model.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
GM - Food industry
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/QJ1230044" target="_blank" >QJ1230044: Determination of parameters for legislative assessing of the quality and safety of raw milk from cows, sheep and goats</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of AOAC International
ISSN
1060-3271
e-ISSN
—
Volume of the periodical
99
Issue of the periodical within the volume
5
Country of publishing house
US - UNITED STATES
Number of pages
5
Pages from-to
1305-1309
UT code for WoS article
000383218500024
EID of the result in the Scopus database
2-s2.0-84988864362