Ultrasensitive detection of influenza viruses with a glycan-based impedimetric biosensor
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F16%3A43909577" target="_blank" >RIV/62156489:43210/16:43909577 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1016/j.bios.2015.12.102" target="_blank" >http://dx.doi.org/10.1016/j.bios.2015.12.102</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.bios.2015.12.102" target="_blank" >10.1016/j.bios.2015.12.102</a>
Alternative languages
Result language
angličtina
Original language name
Ultrasensitive detection of influenza viruses with a glycan-based impedimetric biosensor
Original language description
An ultrasensitive impedimetric glycan-based biosensor for reliable and selective detection of inactivated, but intact influenza viruses H3N2 was developed. Such glycan-based approach has a distinct advantage over antibody-based detection of influenza viruses since glycans are natural viral receptors with a possibility to selectively distinguish between potentially pathogenic influenza subtypes by the glycan-based biosensors. Build-up of the biosensor was carefully optimized with atomic force microscopy applied for visualization of the biosensor surface after binding of viruses with the topology of an individual viral particle H3N2 analyzed. The glycan biosensor could detect a glycan binding lectin with a limit of detection (LOD) of 5 aM. The biosensor was finally applied for analysis of influenza viruses H3N2 with LOD of 13 viral particles in 1 mu l, what is the lowest LOD for analysis of influenza viral particles by the glycan-based device achieved so far. The biosensor could detect H3N2 viruses selectively with a sensitivity ratio of 30 over influenza viruses H7N7. The impedimetric biosensor presented here is the most sensitive glycan-based device for detection of influenza viruses and among the most sensitive antibody or aptamer based biosensor devices.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
CG - Electrochemistry
OECD FORD branch
—
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Biosensors and Bioelectronics
ISSN
0956-5663
e-ISSN
—
Volume of the periodical
79
Issue of the periodical within the volume
May
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
6
Pages from-to
644-649
UT code for WoS article
000370309200088
EID of the result in the Scopus database
2-s2.0-84952888874