Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F62156489%3A43210%2F19%3A43915757" target="_blank" >RIV/62156489:43210/19:43915757 - isvavai.cz</a>
Alternative codes found
RIV/00216224:14310/19:00113358 RIV/62157124:16270/19:43877472
Result on the web
<a href="https://doi.org/10.1007/s00216-019-01904-0" target="_blank" >https://doi.org/10.1007/s00216-019-01904-0</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1007/s00216-019-01904-0" target="_blank" >10.1007/s00216-019-01904-0</a>
Alternative languages
Result language
angličtina
Original language name
Stable-isotope dilution LC-MS/MS method for quantitative determination of microcystin conjugates with cysteine and glutathione in biotic matrices
Original language description
Microcystins are cyclic peptide toxins with hepatotoxic and tumor-promoting properties, which are produced in significant quantities (up to tens of μg/L) in freshwater cyanobacterial water blooms. Several studies reported microcystin accumulation in fish with possible food transfer to humans. These compounds are further metabolized to cysteine and glutathione conjugates which can be present in tissues in significant concentrations. In this study, we focused on the development and evaluation of robust and highly sensitive SPE-LC-MS/MS method for the analysis of microcystin conjugates in fish tissue samples. For the first time, we demonstrate the use of isotopically labeled internal standards which are essential for accurate and precise determination of analytes in complex biotic matrices. LLOQs of respective microcystin conjugates (signal-to-noise ratio; S/N > 10, peak-to-peak method) ranged from 3.3 to 5.0 ng/g of tissue fresh weight (FW). The calibration was linear within a range of concentrations from 1 to 70 ng/mL for all analyzed conjugates. The precision and repeatability of the method were very good with recoveries in the range of 88.5-107.6% and relative standard deviations between 8.8 and 13.2% for all analytes. In the follow-up study, fully validated method was used for the determination of microcystin conjugate levels in common carp exposed to microcystin-containing cyanobacterial biomass under controlled conditions. Significant amounts of microcystin conjugates (up to 55 ng/g) were found in the tissues of fish after 7 weeks of exposure. Our method was shown to be robust, sensitive, selective, and suitable for the determination of trace levels of microcystin conjugates in fish tissues.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10609 - Biochemical research methods
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2019
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Analytical and Bioanalytical Chemistry
ISSN
1618-2642
e-ISSN
—
Volume of the periodical
411
Issue of the periodical within the volume
20
Country of publishing house
DE - GERMANY
Number of pages
9
Pages from-to
5267-5275
UT code for WoS article
000475515600024
EID of the result in the Scopus database
2-s2.0-85066322112