Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985823%3A_____%2F15%3A00455233" target="_blank" >RIV/67985823:_____/15:00455233 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1017/S1431927615015226" target="_blank" >http://dx.doi.org/10.1017/S1431927615015226</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1017/S1431927615015226" target="_blank" >10.1017/S1431927615015226</a>
Alternative languages
Result language
angličtina
Original language name
Total Variation-Based Reduction of Streak Artifacts, Ring Artifacts and Noise in 3D Reconstruction from Optical Projection Tomography
Original language description
Optical projection tomography (OPT) is a computed tomography technique at optical frequencies for samples of 0.5-15 mm in size, which fills an important imaging gap between confocal microscopy (for smaller samples) and large-sample methods such as fluorescence molecular tomography or micro magnetic resonance imaging. OPT operates in either fluorescence or transmission mode. Two-dimensional (2D) projections are taken over 360 degrees with a fixed rotational increment around the vertical axis. Standard 3Dreconstruction from 2D OPT uses the filtered backprojection (FBP) algorithm based on the Radon transform. FBP approximates the inverse Radon transform using a ramp filter that spreads reconstructed pixels to neighbor pixels thus producing streak and other types of artifacts, as well as noise. Artifacts increase the variation of grayscale values in the reconstructed images. We present an algorithm that improves the quality of reconstruction even for a low number of projections by simulta
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
EA - Morphology and cytology
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2015
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Microscopy and Microanalysis
ISSN
1431-9276
e-ISSN
—
Volume of the periodical
21
Issue of the periodical within the volume
6
Country of publishing house
US - UNITED STATES
Number of pages
14
Pages from-to
1602-1615
UT code for WoS article
000366660500024
EID of the result in the Scopus database
—