Enzymatic Sensor of Putrescine with Optical Oxygen Transducer - Mathematical Model of Responses of Sensitive Layer.

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F15%3A00438314" target="_blank" >RIV/67985858:_____/15:00438314 - isvavai.cz</a>

  • Alternative codes found

    RIV/61989592:15310/15:33156957 RIV/60461373:22340/15:43900196

  • Result on the web

    <a href="http://dx.doi.org/10.1515/chempap-2015-0041" target="_blank" >http://dx.doi.org/10.1515/chempap-2015-0041</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1515/chempap-2015-0041" target="_blank" >10.1515/chempap-2015-0041</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Enzymatic Sensor of Putrescine with Optical Oxygen Transducer - Mathematical Model of Responses of Sensitive Layer.

  • Original language description

    A biosensor for putrescine containing a sensing layer with an optical oxygen probe based on ruthenium complex and the enzyme diamine oxidase from pea is described. The diamine oxidase was pre-immobilised on broken micro-beads modified with a ferrofluid.The pre-immobilised enzyme and ruthenium complex were both incorporated into the UV-cured inorganic?organic hybrid polymer ORMOCER and deposited on a lens to form a sensitive layer of 210 ?m in thickness. The sensitivity to the putrescine concentration determined under air saturation was between 3.50 ?s L mmol-1 and 4.50 ?s L mmol-1 in a hundred experiments conducted intermittently over a one year period. With the oxygen concentration increasing from 10 % to 100 % of DO (dissolved oxygen), the biosensorsensitivity decreased from 6.87 ?s L mmol-1 to 0.70 ?s L mmol-1 and its dynamic range increased from 0.10 mmol L-1 to 1.75 mmol L-1. To estimate the behaviour of the putrescine sensor in parametric space, a mathematical model of the reac

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CE - Biochemistry

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Chemical Papers

  • ISSN

    0366-6352

  • e-ISSN

  • Volume of the periodical

    69

  • Issue of the periodical within the volume

    1

  • Country of publishing house

    SK - SLOVAKIA

  • Number of pages

    9

  • Pages from-to

    158-166

  • UT code for WoS article

    000350130100014

  • EID of the result in the Scopus database