All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Decontamination of Oils Contaminated with Polychlorinated Biphenyls and Dibenzyl Disulfide Using Polar Aprotic Solvents

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985858%3A_____%2F15%3A00445923" target="_blank" >RIV/67985858:_____/15:00445923 - isvavai.cz</a>

  • Result on the web

    <a href="http://www.ijesit.com/Volume%204/Issue%202/IJESIT201502_06.pdf" target="_blank" >http://www.ijesit.com/Volume%204/Issue%202/IJESIT201502_06.pdf</a>

  • DOI - Digital Object Identifier

Alternative languages

  • Result language

    angličtina

  • Original language name

    Decontamination of Oils Contaminated with Polychlorinated Biphenyls and Dibenzyl Disulfide Using Polar Aprotic Solvents

  • Original language description

    The highest efficiency, around 70 % in single-step extraction exhibited NMP. NMP was evaluated as having the best chance to be used in industry. It was shown that for some transformer oils the separation of corrosive sulfur with the common technique of filtration through a layer of commercially available sorbent (for example Fuller?s earth) is totally inadequate. However, extraction efficiency of DBDS from contaminated transformer oil with the help of NMP is sufficiently high over 99 % and feasible in afair time of about 20 minutes. The remaining concentration of DBDS after single-step extraction from transformer oil containing up to100 ppm DBDS was low enough (approx. 0.1 ppm or non-detectable). Detection of corrosive sulfur in transformer oil afterextraction with NMP has been also performed by Siemens test method (IEC 62535) and by updated ASTM 1275B proposed by CIGRE Covered Conductor Deposition test method and was negative. It is possible to consider the transformer oil after the

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CI - Industrial chemistry and chemical engineering

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/TA04020151" target="_blank" >TA04020151: Enhancement of the power transformer operation security and prevention of their failures caused by the corrosive sulphur effect</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    International Journal of Engineering Science and Innovative Technology. ON -LINE

  • ISSN

    2319-5967

  • e-ISSN

  • Volume of the periodical

    4

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    IN - INDIA

  • Number of pages

    8

  • Pages from-to

    41-48

  • UT code for WoS article

  • EID of the result in the Scopus database