Biofunctionalized gold nanoparticles for SPR-biosensor-based detection of CEA in blood plasma

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F12%3A00396508" target="_blank" >RIV/67985882:_____/12:00396508 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s00216-012-6308-9" target="_blank" >http://dx.doi.org/10.1007/s00216-012-6308-9</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00216-012-6308-9" target="_blank" >10.1007/s00216-012-6308-9</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Biofunctionalized gold nanoparticles for SPR-biosensor-based detection of CEA in blood plasma

  • Original language description

    We report on the use of new biofunctionalized gold nanoparticles (bio-AuNPs) that enable a surface plasmon resonance (SPR) biosensor to detect low levels of carcinoembryonic antigen (CEA) in human blood plasma. Bio-AuNPs consist of gold nanoparticles functionalized both with (1) streptavidin, to provide high affinity for the biotinylated secondary antibody used in the second step of the CEA sandwich assay, and with (2) bovine serum albumin, to minimize the nonspecific interaction of the bio-AuNPs with complex samples (blood plasma). We demonstrate that this approach makes it possible for the SPR biosensor to detect CEA in blood plasma at concentrations as low as 0.1 ng/mL, well below normal physiological levels (approximately nanograms per milliliter).Moreover, the limit of detection achieved using this approach is better by a factor of more than 1,000 than limits of detection reported so far for CEA in blood plasma using SPR biosensors.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JB - Sensors, detecting elements, measurement and regulation

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2012

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical and Bioanalytical Chemistry

  • ISSN

    1618-2642

  • e-ISSN

  • Volume of the periodical

    51

  • Issue of the periodical within the volume

    10

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    7

  • Pages from-to

    2869-2875

  • UT code for WoS article

    000311310100010