All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Functional gold nanoparticles for optical affinity biosensing

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985882%3A_____%2F17%3A00484790" target="_blank" >RIV/67985882:_____/17:00484790 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1007/s00216-017-0355-1" target="_blank" >http://dx.doi.org/10.1007/s00216-017-0355-1</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1007/s00216-017-0355-1" target="_blank" >10.1007/s00216-017-0355-1</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Functional gold nanoparticles for optical affinity biosensing

  • Original language description

    Functional gold nanoparticles (AuNPs) are commonly used to enhance the response of optical affinity biosensors. In this work, we investigated the effect of preparation conditions on functional properties of AuNPs functionalized with antibody (Ab-AuNPs), specifically AuNPs with antibody against carcinoembryonic antigen (CEA) covalently attached via carboxy-terminated oligo-ethylene thiolate linker layer. The following parameters of preparation of Ab-AuNP have been found to have a significant effect on Ab-AuNP performance in affinity biosensors: the time of reaction of activated AuNPs with antibody, concentrations of antibody and amino-coupling reagents, and composition of immobilization buffer (molarity and salt content). In contrast, pH of immobilization buffer has been demonstrated to have only a minor influence. Our experiments showed that the Ab-AuNPs prepared under optimum conditions offered a binding efficiency of Ab-AuNPs to CEA as high as 63%, which is more than 4 times better than the best efficiencies reported for similar functional AuNPs so far. We employed these Ab-AuNPs with a surface plasmon resonance (SPR) biosensor for the detection of CEA and showed that the Ab-AuNPs enhanced the sensor response to CEA by a factor of 1000. We also demonstrated that the Ab-AuNPs allow the biosensor to detect CEA at concentrations as low as 12 and 40 pg/mL in buffer and 50% blood plasma, respectively

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])

Result continuities

  • Project

    <a href="/en/project/GBP205%2F12%2FG118" target="_blank" >GBP205/12/G118: Nanobiophotonics for future health care</a><br>

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytical and Bioanalytical Chemistry

  • ISSN

    1618-2642

  • e-ISSN

  • Volume of the periodical

    409

  • Issue of the periodical within the volume

    16

  • Country of publishing house

    DE - GERMANY

  • Number of pages

    11

  • Pages from-to

    4087-4097

  • UT code for WoS article

    000401787700019

  • EID of the result in the Scopus database

    2-s2.0-85017517705