Methodology for the Implementation of Internal Standard to Laser-Induced Breakdown Spectroscopy Analysis of Soft Tissues
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F67985904%3A_____%2F21%3A00541279" target="_blank" >RIV/67985904:_____/21:00541279 - isvavai.cz</a>
Alternative codes found
RIV/00216305:26620/21:PU139473 RIV/00216224:14310/21:00121308 RIV/00216208:11150/21:10422540 RIV/00216208:11120/21:43921095
Result on the web
<a href="https://www.mdpi.com/1424-8220/21/3/900" target="_blank" >https://www.mdpi.com/1424-8220/21/3/900</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.3390/s21030900" target="_blank" >10.3390/s21030900</a>
Alternative languages
Result language
angličtina
Original language name
Methodology for the Implementation of Internal Standard to Laser-Induced Breakdown Spectroscopy Analysis of Soft Tissues
Original language description
The improving performance of the laser-induced breakdown spectroscopy (LIBS) triggered its utilization in the challenging topic of soft tissue analysis. Alterations of elemental content within soft tissues are commonly assessed and provide further insights in biological research. However, the laser ablation of soft tissues is a complex issue and demands a priori optimization, which is not straightforward in respect to a typical LIBS experiment. Here, we focus on implementing an internal standard into the LIBS elemental analysis of soft tissue samples. We achieve this by extending routine methodology for optimization of soft tissues analysis with a standard spiking method. This step enables a robust optimization procedure of LIBS experimental settings. Considering the implementation of LIBS analysis to the histological routine, we avoid further alterations of the tissue structure. Therefore, we propose a unique methodology of sample preparation, analysis, and subsequent data treatment, which enables the comparison of signal response from heterogenous matrix for different LIBS parameters. Additionally, a brief step-by-step process of optimization to achieve the highest signal-to-noise ratio (SNR) is described. The quality of laser-tissue interaction is investigated on the basis of the zinc signal response, while selected experimental parameters (e.g., defocus, gate delay, laser energy, and ambient atmosphere) are systematically modified.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10609 - Biochemical research methods
Result continuities
Project
—
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2021
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Sensors
ISSN
1424-8220
e-ISSN
1424-8220
Volume of the periodical
21
Issue of the periodical within the volume
3
Country of publishing house
CH - SWITZERLAND
Number of pages
13
Pages from-to
900
UT code for WoS article
000615488400001
EID of the result in the Scopus database
2-s2.0-85099932691