All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

New methodology for capillary electrophoresis with ESI-MS detection: Electrophoretic focusing on inverse electromigration dispersion gradient. High-sensitivity analysis of sulfonamides in waters

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081715%3A_____%2F16%3A00460851" target="_blank" >RIV/68081715:_____/16:00460851 - isvavai.cz</a>

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.aca.2016.06.016" target="_blank" >http://dx.doi.org/10.1016/j.aca.2016.06.016</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.aca.2016.06.016" target="_blank" >10.1016/j.aca.2016.06.016</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    New methodology for capillary electrophoresis with ESI-MS detection: Electrophoretic focusing on inverse electromigration dispersion gradient. High-sensitivity analysis of sulfonamides in waters

  • Original language description

    This article describes for the first time the combination of electrophoretic focusing on inverse electromigration dispersion (EMD) gradient, a new separation principle described in 2010, with electrosprayionization (ESI) mass spectrometric detection. The separation of analytes along the electromigrating EMD profile proceeds so that each analyte is focused and concentrated within the profile at a particular position given by its pKa and ionic mobility. The proposed methodology combines this principle with the transport of the focused zones to the capillary end by superimposed electromigration, electroosmotic flow and ESI suction, and their detection by the MS detector. The designed electrolyte system based on maleic acid and 2,6-lutidine is suitable to create an inverse EMD gradient of required properties and its components are volatile enough to be compatible with the ESI interface.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    CB - Analytical chemistry, separation

  • OECD FORD branch

Result continuities

  • Project

    <a href="/en/project/GA16-09135S" target="_blank" >GA16-09135S: Novel microextraction approaches for clean-up, preconcentration and analysis of samples with complex matrices.</a><br>

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2016

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Analytica Chimica Acta

  • ISSN

    0003-2670

  • e-ISSN

  • Volume of the periodical

    935

  • Issue of the periodical within the volume

    SEP

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    9

  • Pages from-to

    249-257

  • UT code for WoS article

    000382249600023

  • EID of the result in the Scopus database

    2-s2.0-84990210308