Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F13%3A00421676" target="_blank" >RIV/68081731:_____/13:00421676 - isvavai.cz</a>
Alternative codes found
RIV/00159816:_____/13:00060567 RIV/00216305:26220/13:PU102196
Result on the web
<a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >http://dx.doi.org/10.1088/0967-3334/34/2/151</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >10.1088/0967-3334/34/2/151</a>
Alternative languages
Result language
angličtina
Original language name
Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents
Original language description
Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of thedeveloped tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time va
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
FS - Medical facilities, apparatus and equipment
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Physiological Measurement
ISSN
0967-3334
e-ISSN
—
Volume of the periodical
34
Issue of the periodical within the volume
2
Country of publishing house
GB - UNITED KINGDOM
Number of pages
12
Pages from-to
151-162