All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F13%3A00421676" target="_blank" >RIV/68081731:_____/13:00421676 - isvavai.cz</a>

  • Alternative codes found

    RIV/00159816:_____/13:00060567 RIV/00216305:26220/13:PU102196

  • Result on the web

    <a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >http://dx.doi.org/10.1088/0967-3334/34/2/151</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1088/0967-3334/34/2/151" target="_blank" >10.1088/0967-3334/34/2/151</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Comparison and evaluation of indicator dilution models for bolus of ultrasound contrast agents

  • Original language description

    Dynamic contrast-enhanced ultrasound (DCE-US) imaging is a promising diagnostic method, which enables the evaluation of tissue perfusion via different parameters. The mean transit time and time-to-peak parameters are the main time parameters and their values depend on the model used for the approximation of the noisy perfusion curves. In this paper, we described a new comparison of different perfusion models using a tissue mimicking phantom. The following models were compared: log-normal, lagged, Erlang, Gamma and the local density random walk model. We discovered that the mean-square error is not the best criterion for model evaluation. More important is the comparison between the estimated time perfusion parameters and the physical parameters of thedeveloped tissue mimicking phantom. Based on the statistical analysis, we can suggest that for the DCE-US perfusion analysis more models should be used, excluding the log-normal model, which gives the highest error of mean transit time va

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    FS - Medical facilities, apparatus and equipment

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    I - Institucionalni podpora na dlouhodoby koncepcni rozvoj vyzkumne organizace

Others

  • Publication year

    2013

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Physiological Measurement

  • ISSN

    0967-3334

  • e-ISSN

  • Volume of the periodical

    34

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    GB - UNITED KINGDOM

  • Number of pages

    12

  • Pages from-to

    151-162

  • UT code for WoS article

    000314287500004

  • EID of the result in the Scopus database