In Situ Study of Internal Structure of Spherical Polyelectrolyte Complex Capsules Using ESEM
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F16%3A00465246" target="_blank" >RIV/68081731:_____/16:00465246 - isvavai.cz</a>
Result on the web
<a href="http://onlinelibrary.wiley.com/doi/10.1002/9783527808465.EMC2016.5932/pdf" target="_blank" >http://onlinelibrary.wiley.com/doi/10.1002/9783527808465.EMC2016.5932/pdf</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1002/9783527808465.EMC2016.5932" target="_blank" >10.1002/9783527808465.EMC2016.5932</a>
Alternative languages
Result language
angličtina
Original language name
In Situ Study of Internal Structure of Spherical Polyelectrolyte Complex Capsules Using ESEM
Original language description
Polyelectrolyte complex (PEC) capsules/beads are very important for biotechnological applications such as drug delivery and bacterial whole-cell biocatalyst development. The very beam-sensitive bio-polymer capsules are laboratory produced as a uniform with a controlled shape, size, membrane thickness, permeability and mechanical resistance. PEC capsules are very sensitive to any treatment and samples could be inspected in their fully native and functional state to prevent any misinterpretation. Characterization and study of PEC capsules properties is possible using thermodynamically stabile and fully wet state, precisely reached after very slow changing of conditions in the specimen chamber of ESEM. The morphological study using low current ESEM was already presented. The internal structure can be in solvent, semisolid or solid state, depend on capsule type and manufacturing process, nevertheless it was not described in its native state yet. Study of inner part as well as surface morphology of PEC capsules using classical SEM or cryo-SEM can be misleading due to requirement of dry resp. freeze sample. The aim of this work is in-situ study of internal structure of PEC capsules in fully wet state and demonstration of state of matter of PEC capsules core.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
Result was created during the realization of more than one project. More information in the Projects tab.
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2016
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
EMC2016. The 16th European Microscopy Congress. Proceedings
ISBN
9783527808465
ISSN
—
e-ISSN
—
Number of pages
2
Pages from-to
—
Publisher name
Wiley
Place of publication
Oxford
Event location
Lyon
Event date
Aug 28, 2016
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
—