Evaluation of magnetic resonance imaging issues of titanium and stainless steel brackets

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68081731%3A_____%2F19%3A00509771" target="_blank" >RIV/68081731:_____/19:00509771 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216208:11110/19:10399792

  • Result on the web

    <a href="http://scienceasia.org/content/viewabstract.php?ms=9355&v=" target="_blank" >http://scienceasia.org/content/viewabstract.php?ms=9355&v=</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.2306/scienceasia1513-1874.2019.45.145" target="_blank" >10.2306/scienceasia1513-1874.2019.45.145</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Evaluation of magnetic resonance imaging issues of titanium and stainless steel brackets

  • Original language description

    Magnetic resonance imaging (MRI) is a sophisticated diagnostic method of contemporary medicine. This examination in patients with metallic objects is often complicated due to MRI issues. Clinically significant difference in MRI issues of titanium (equilibrium ti, Dentaurum) and stainless steel (Gemini, 3M Unitec) brackets was studied in a clinical 1.5 T and an experimental 4.7 T MRI scanners. In this in vitro study, the following parameters were assessed: artefacts, magnetic field interaction, and heating. Artefacts were evaluated in spin and gradient echo images using ASTM F2119-07 standard in 1.5 T field. Translational attraction, torque and heating were tested. The titanium bracket for upper lateral incisor produced 2.5-4.3 mm and 4.7-4.9 mm artefacts in spin and gradient echo scans, respectively. The stainless steel bracket for upper lateral incisor caused more than 50 mm distortions in the same sequences. Images of the titanium bracket set were diagnostically acceptable whereas the stainless steel bracket set could not be graded due to the incapability of the MRI scanner to adjust resonance frequency. No clinically relevant translational attraction and no torque were detected for equilibrium ti brackets, while Gemini brackets were strongly attracted by the magnetic field. No clinically significant heating was observed. Noticeable difference in MRI issues of the brackets was observed in artefacts and mobility. Gemini brackets were found unacceptable for MRI.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2019

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    ScienceAsia

  • ISSN

    1513-1874

  • e-ISSN

  • Volume of the periodical

    45

  • Issue of the periodical within the volume

    2

  • Country of publishing house

    TH - THAILAND

  • Number of pages

    9

  • Pages from-to

    145-153

  • UT code for WoS article

    000471836300006

  • EID of the result in the Scopus database

    2-s2.0-85069924957