Effects of Continuous and Pulsating Water Jet on CNT/Concrete Composite

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68145535%3A_____%2F17%3A00482312" target="_blank" >RIV/68145535:_____/17:00482312 - isvavai.cz</a>

  • Alternative codes found

    RIV/00216305:26110/17:PU126768 RIV/61989100:27640/17:10237691 RIV/61989100:27740/17:10237691

  • Result on the web

    <a href="http://ojs.sv-jme.eu/index.php/sv-jme/article/view/sv-jme.2017.4357" target="_blank" >http://ojs.sv-jme.eu/index.php/sv-jme/article/view/sv-jme.2017.4357</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.5545/sv-jme.2017.4357" target="_blank" >10.5545/sv-jme.2017.4357</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Effects of Continuous and Pulsating Water Jet on CNT/Concrete Composite

  • Original language description

    This paper presents first results of the study of the resistance of carbon nanotube concrete composite (CNT/concrete composite) to the action of continuous and pulsating water jets. The experiments oriented at the determination of erosion effects of pulsating and continuous water jets impinging the surface of reference (concrete) and CNT/concrete composite samples were performed. Tested samples were characterized by X-ray powder diffraction and scanning electron microscope. Samples were exposed to pulsating and continuous water jets at various operating parameters. Erosion effects of pulsating and continuous jets were evaluated in terms of material removal rate. The possible influence of addition of CNTs to the concrete on its resistance to the action of continuous and pulsating water jets is discussed in the paper. The experiments proved that CNT/concrete composite exhibits higher resistance than reference concrete to the action of both pulsating and continuous water jet under the given testing conditions.

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database

  • CEP classification

  • OECD FORD branch

    20101 - Civil engineering

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2017

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Strojniski Vestnik-Journal of Mechanical Engineering

  • ISSN

    0039-2480

  • e-ISSN

  • Volume of the periodical

    63

  • Issue of the periodical within the volume

    10

  • Country of publishing house

    HR - CROATIA

  • Number of pages

    7

  • Pages from-to

    583-589