Temperature of External Column During Fire Test
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F10%3A00216262" target="_blank" >RIV/68407700:21110/10:00216262 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Temperature of External Column During Fire Test
Original language description
The temperature of steel column located outside the fire compartment was studied during fire test in Mokrsko (carried out in September 2008) [1], [2]. The column was placed in front of the compartment window. The measured temperatures were used to validate numerical models of heat transfer. There are two models described: FEM model using software Ansys and software for prediction of column temperature developed at CTU in Prague.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
JM - Structural engineering
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/1M0579" target="_blank" >1M0579: Centre for Integrated Design of Advanced Structures</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2010
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Structures in Fire
ISBN
978-1-60595-027-3
ISSN
—
e-ISSN
—
Number of pages
8
Pages from-to
83-90
Publisher name
Michigan State University
Place of publication
East Lansing, Michigan
Event location
East Lansing
Event date
Jun 2, 2010
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000282623900011