Absolute Baseline for Testing of Electronic Distance Meters
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F14%3A00217401" target="_blank" >RIV/68407700:21110/14:00217401 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Absolute Baseline for Testing of Electronic Distance Meters
Original language description
The paper deals with the construction and determination of coordinates of the absolute EDMs baseline in a laboratory with 16 pillars with forced centring. Leica Absolute Tracker AT401 (standard deviation of distance measurement: 5 ?m, standard deviationof angle measurement: 0.15 mgon), which is designed for very accurate industrial measurements, was used for our purpose. Lengths between the baseline points were determined with a standard deviation of 0.02 mm. The baseline is used for determining systematic and random errors of distance meters and for accuracy of distance meters at short distances common in engineering surveying for purposes of mechanical engineering.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
DE - Earth magnetism, geodesy, geography
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2014
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
INGEO 2014
ISBN
978-80-01-05469-7
ISSN
—
e-ISSN
—
Number of pages
6
Pages from-to
275-280
Publisher name
České vysoké učení technické v Praze
Place of publication
Praha
Event location
Praha
Event date
Apr 3, 2014
Type of event by nationality
EUR - Evropská akce
UT code for WoS article
—