All

What are you looking for?

All
Projects
Results
Organizations

Quick search

  • Projects supported by TA ČR
  • Excellent projects
  • Projects with the highest public support
  • Current projects

Smart search

  • That is how I find a specific +word
  • That is how I leave the -word out of the results
  • “That is how I can find the whole phrase”

Changes in Energy and Temperature in the Ground Mass with Horizontal Heat Exchangers - The Energy Source for Heat Pumps

The result's identifiers

  • Result code in IS VaVaI

    <a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F15%3A00226750" target="_blank" >RIV/68407700:21110/15:00226750 - isvavai.cz</a>

  • Alternative codes found

    RIV/60460709:41310/15:67010

  • Result on the web

    <a href="http://dx.doi.org/10.1016/j.enbuild.2015.01.052" target="_blank" >http://dx.doi.org/10.1016/j.enbuild.2015.01.052</a>

  • DOI - Digital Object Identifier

    <a href="http://dx.doi.org/10.1016/j.enbuild.2015.01.052" target="_blank" >10.1016/j.enbuild.2015.01.052</a>

Alternative languages

  • Result language

    angličtina

  • Original language name

    Changes in Energy and Temperature in the Ground Mass with Horizontal Heat Exchangers - The Energy Source for Heat Pumps

  • Original language description

    This article addresses soil temperature analysis, heat flows and energy transferred from the soil massif via a linear horizontal heat exchanger and horizontal heat exchanger of Slinky type. Heat exchangers are used as low-potential sources of thermal energy for heat pumps. Both exchangers were compared in terms of their influence on the soil massif temperature in the exchanger area, and on the exchanger power output. The exchangers were evaluated in the heating periods of 2011 - 2012, 2012 - 2013 and inthe exchanger stagnation period of 2011. The linear heat exchanger seems to be more suitable as a low-potential power supply for heat pumps. The average temperatures of the soil massif in the exchanger areas were positive in both heating periods and thetemperature was higher at the linear exchanger. The temperatures of the heat-transfer fluid exiting the exchangers were positive and the linear exchanger temperature was higher. The temperatures of the heat-transfer fluid entering the ex

  • Czech name

  • Czech description

Classification

  • Type

    J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)

  • CEP classification

    JE - Non-nuclear power engineering, energy consumption and utilization

  • OECD FORD branch

Result continuities

  • Project

    Result was created during the realization of more than one project. More information in the Projects tab.

  • Continuities

    P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)

Others

  • Publication year

    2015

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Data specific for result type

  • Name of the periodical

    Energy and Buildings

  • ISSN

    0378-7788

  • e-ISSN

  • Volume of the periodical

    92

  • Issue of the periodical within the volume

    April

  • Country of publishing house

    NL - THE KINGDOM OF THE NETHERLANDS

  • Number of pages

    9

  • Pages from-to

    107-115

  • UT code for WoS article

    000351786900010

  • EID of the result in the Scopus database

    2-s2.0-84923069727