Hygrothermal analysis of surface layers of historical masonry
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21110%2F17%3A00316223" target="_blank" >RIV/68407700:21110/17:00316223 - isvavai.cz</a>
Result on the web
<a href="http://dx.doi.org/10.1063/1.5012417" target="_blank" >http://dx.doi.org/10.1063/1.5012417</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1063/1.5012417" target="_blank" >10.1063/1.5012417</a>
Alternative languages
Result language
angličtina
Original language name
Hygrothermal analysis of surface layers of historical masonry
Original language description
The paper deals with the hygrothermal analysis of surface layers of historical masonry. Solid brick provided with a traditional and two modified lime-based plasters is studied. The heat and moisture transport in the envelope is induced by an exposure of the wall from the exterior side to dynamic climatic conditions of Olomouc, Czech Republic. The transport processes are described using diffusion type of mathematical model based on experimentally determined material properties. The computational results indicate that hygric transport and accumulation properties of exterior plasters affect the hygrothermal performance of the underlying solid brick in a very significant way, being able to regulate the amount of transported moisture. The modified lime plasters are not found generally superior to the traditional lime plasters in that respect. Therefore, their suitability for historical masonry should be assessed case by case, with a particular attention to the climatic conditions and to the properties of the load bearing structure.
Czech name
—
Czech description
—
Classification
Type
D - Article in proceedings
CEP classification
—
OECD FORD branch
60101 - History (history of science and technology to be 6.3, history of specific sciences to be under the respective headings)
Result continuities
Project
<a href="/en/project/DG16P02H046" target="_blank" >DG16P02H046: Interior thermal insulation systems for the architectural-heritage domain</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Article name in the collection
Proceedings of the International Conference of Computational Methods in Sciences and Engineering 2017
ISBN
978-0-7354-1596-6
ISSN
—
e-ISSN
1551-7616
Number of pages
4
Pages from-to
—
Publisher name
AIP Conference Proceedings
Place of publication
New York
Event location
Thessaloniki
Event date
Apr 21, 2017
Type of event by nationality
WRD - Celosvětová akce
UT code for WoS article
000419835900126