Influence of air distribution on flow field in freeboard area in a bubbling fluidized bed boiler
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00210376" target="_blank" >RIV/68407700:21220/13:00210376 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Influence of air distribution on flow field in freeboard area in a bubbling fluidized bed boiler
Original language description
One of the basic functions of the air distributor is to provide uniform fluidization and homogenous flow field above the bed. Thus demand of CFD simulation arises from needs to understand behaviour of the fluidized bed. Situation in this case is complicated by the trough-shaped air distributor. The paper deals with 2D CFD simulations of fluidized bed and confronts it with experimental measurements on pilot scale unit. Simulations and measurements are done under ambient conditions without combustion. Simplified geometry was built up in Gambit and CFD simulations are done by ANSYS FLUENT.
Czech name
—
Czech description
—
Classification
Type
O - Miscellaneous
CEP classification
BK - Liquid mechanics
OECD FORD branch
—
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2013
Confidentiality