LHCb experimental setup (air cooling option)
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21220%2F13%3A00211093" target="_blank" >RIV/68407700:21220/13:00211093 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
LHCb experimental setup (air cooling option)
Original language description
We have built a testing cooling prototype apparatus for the LHCB SciFi particle detector endcap mockups. This detector is currently under development and it is foreseen to be used in the LHC accelerator in CERN. The silicon photomultipliers in the endcapmodules needs to be cooled and for that purpose a different designs of air heat exchangers were tested. The AIRCOOLER_II, which was developed at the CTU Department of Applied Physics, was the core of the test setup. The AIRCOOLER_II is an arrangement ofvortex tubes producing a stream of air as cold as -50°C. The input compressed air was passing through a Donaldson Ultrapac 2000 type 0050 dryer and its flow was measured using the Azbil 0-500l/min flow meter. The produced cold air flow was measured by the Red-Y Smart flow meter. AIRCOOLER itself was equipped with three SensorTechnics pressure sensors and with seven temperature sensors. There were at least ten temperature sensors placed in each mockup with inner heat exchanger and photom
Czech name
—
Czech description
—
Classification
Type
G<sub>funk</sub> - Functional sample
CEP classification
BF - Elementary particle theory and high energy physics
OECD FORD branch
—
Result continuities
Project
<a href="/en/project/LG13031" target="_blank" >LG13031: Collaboration of the Czech Republic with CERN</a><br>
Continuities
P - Projekt vyzkumu a vyvoje financovany z verejnych zdroju (s odkazem do CEP)
Others
Publication year
2013
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Internal product ID
LHCb_Aircooler_II_2013
Numerical identification
—
Technical parameters
Rack 1m x 2m x 1m; Aicooler_II; DAQ systém a senzory; zásobník tlak. vzduchu
Economical parameters
100 000 Kč
Application category by cost
—
Owner IČO
68407700
Owner name
ČVUT FSI
Owner country
CZ - CZECH REPUBLIC
Usage type
P - Využití výsledku jiným subjektem je v některých případech možné bez nabytí licence
Licence fee requirement
Z - Poskytovatel licence na výsledek nepožaduje v některých případech licenční poplatek