Contactless Current Measurement Device with the Anisotropic Magnetoresistors
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F05%3A03108950" target="_blank" >RIV/68407700:21230/05:03108950 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Contactless Current Measurement Device with the Anisotropic Magnetoresistors
Original language description
A device for the contactless current measurement with Anisotropic Magnetoresistive sensors (AMR) has been developed. As the AMRs are much more sensitive than classically used Hall sensors, no magnetic concentrator is needed. The realized device reaches so far the linearity error of ą60 ppm in the current range of ą11 A for DC, i.e. the absolute resolution is ą1.3 mA. And the error due to non-concentric wire is less then ą0.6 %. The influence of the external current is reduced more then 45 dB.
Czech name
Není k dispozici
Czech description
Není k dispozici
Classification
Type
A - Audiovisual production
CEP classification
JB - Sensors, detecting elements, measurement and regulation
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2005
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
ISBN
—
Place of publication
Praha
Publisher/client name
—
Version
—
Carrier ID