Rerence noise method of removing powerline noise from recorded signals
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F09%3A00157727" target="_blank" >RIV/68407700:21230/09:00157727 - isvavai.cz</a>
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Rerence noise method of removing powerline noise from recorded signals
Original language description
Powerline contamination of recorded signals represents a major source of noise in electrophysiology and impairs the use of recordings for research. In this article we present simple and effective method for cancelling 50 Hz (or 60 Hz) noise using a reference noise signal and average noise cycle subtraction. This method is capable of reliably removing not only the fundamental powerline frequency but also its harmonic frequencies. The efficiency of this method appears to be superior to other commonly usedmethods such as notch filtering or adaptive filtering. Our experience and results show that this method can be efficiently used with very low signal-to-noise ratios, while preserving original signal waveform.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
JA - Electronics and optoelectronics
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)
Others
Publication year
2009
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Neuroscience Methods
ISSN
0165-0270
e-ISSN
—
Volume of the periodical
184
Issue of the periodical within the volume
1
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
5
Pages from-to
—
UT code for WoS article
000271053400014
EID of the result in the Scopus database
—