Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21230%2F23%3A00367209" target="_blank" >RIV/68407700:21230/23:00367209 - isvavai.cz</a>
Result on the web
<a href="https://doi.org/10.1016/j.chroma.2023.464180" target="_blank" >https://doi.org/10.1016/j.chroma.2023.464180</a>
DOI - Digital Object Identifier
<a href="http://dx.doi.org/10.1016/j.chroma.2023.464180" target="_blank" >10.1016/j.chroma.2023.464180</a>
Alternative languages
Result language
angličtina
Original language name
Application of solid-phase microextraction arrows for characterizing volatile organic compounds from 3D printing of acrylonitrile-styrene-acrylate filament
Original language description
3D printing is an extensively used manufacturing technique that can pose specific health concerns due to the emission of volatile organic compounds (VOC). Herein, a detailed characterization of 3D printing-related VOC using solid-phase microextraction-gas chromatography/mass spectrometry (SPME-GC/MS) is described for the first time. The VOC were extracted in dynamic mode during the printing from the acrylonitrile-styrene-acrylate filament in an environmental chamber. The effect of extraction time on the extraction efficiency of 16 main VOC was studied for four different commercial SPME arrows. The volatile and semivolatile compounds were the most effectively extracted by carbon wide range-containing and polydimethyl siloxane arrows, respectively. The differences in extraction efficiency between arrows were further correlated to the molecular volume, octanol-water partition coefficient, and vapour pressure of observed VOC. The repeatability of SPME arrows towards the main VOC was assessed from static mode measurements of filament in headspace vials. In addition, we performed a group analysis of 57 VOC clas-sified into 15 categories according to their chemical structure. Divinylbenzene-polydimethyl siloxane ar-row turned out to be a good compromise between the total extracted amount and its distribution among tested VOC. Thus, this arrow was used to demonstrate the usefulness of SPME for the qualification of VOC emitted during printing in a real-life environment. A presented methodology can serve as a fast and reliable method for the qualification and semi-quantification of 3D printing-related VOC.
Czech name
—
Czech description
—
Classification
Type
J<sub>imp</sub> - Article in a specialist periodical, which is included in the Web of Science database
CEP classification
—
OECD FORD branch
10406 - Analytical chemistry
Result continuities
Project
—
Continuities
S - Specificky vyzkum na vysokych skolach
Others
Publication year
2023
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Journal of Chromatography A
ISSN
0021-9673
e-ISSN
1873-3778
Volume of the periodical
1705
Issue of the periodical within the volume
8
Country of publishing house
NL - THE KINGDOM OF THE NETHERLANDS
Number of pages
14
Pages from-to
—
UT code for WoS article
001032122700001
EID of the result in the Scopus database
2-s2.0-85163845963