Biofeedback as a neurobiomechanical aspect of postural function
The result's identifiers
Result code in IS VaVaI
<a href="https://www.isvavai.cz/riv?ss=detail&h=RIV%2F68407700%3A21260%2F17%3A00317326" target="_blank" >RIV/68407700:21260/17:00317326 - isvavai.cz</a>
Alternative codes found
RIV/68407700:21460/17:00317326
Result on the web
—
DOI - Digital Object Identifier
—
Alternative languages
Result language
angličtina
Original language name
Biofeedback as a neurobiomechanical aspect of postural function
Original language description
The aim of the work is to elucidate if there is a significant difference between the ability to maintain balance with or without the biofeedback while standing and identify specific segments that takes place of motion solutions of postural problems. We measured postural parameters using 6 tri-axial accelerometers placed in 6 places: 2x lower leg, 2x thigh, processus spinosus vertebrae L5 and C7. Probands absolved 3 postural tasks and 3 dynamic tasks. Postural: quiet standing with feet apart with eyes open, quiet standing with feet together with eye closed, quiet standing with feet apart with eyes open and with visual biofeedback. We used system Homebalance-interactive system for providing of balance training with visual biofeedback. Results show no significant difference between C7 and L5 for task without VBF (visual biofeedback) and with VBF, but SD VPG (sum of scatter of the acceleration) for thigh and ankle show significant difference between each task on every level. We detected that in open eyes majority of probands used anklestrategy for maintaining balance. In eyes closed they preferred knee and hip strategy. The biggest accelerations were detected in C7 in eyes closed. Due to visual biofeedback patients are more motivated and they improve their skills faster than without visual biofeedback exercise. Strategy of maintaining balance during tasks with open eyes and eyes closed is different.
Czech name
—
Czech description
—
Classification
Type
J<sub>SC</sub> - Article in a specialist periodical, which is included in the SCOPUS database
CEP classification
—
OECD FORD branch
20602 - Medical laboratory technology (including laboratory samples analysis; diagnostic technologies) (Biomaterials to be 2.9 [physical characteristics of living material as related to medical implants, devices, sensors])
Result continuities
Project
—
Continuities
N - Vyzkumna aktivita podporovana z neverejnych zdroju
Others
Publication year
2017
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Lékař a technika
ISSN
0301-5491
e-ISSN
2336-5552
Volume of the periodical
47
Issue of the periodical within the volume
1
Country of publishing house
CZ - CZECH REPUBLIC
Number of pages
4
Pages from-to
19-22
UT code for WoS article
—
EID of the result in the Scopus database
2-s2.0-85026323644