Photon Counting Module for Laser Time Transfer Space Project

Result description

We are presenting the results of research and development of the Single Photon Avalanche Detector (SPAD) for application in a Laser Time Transfer (LTT) space mission. For this joint project with the Shanghai Observatory, Academy of Sciences of China, wehave developed a detector package dedicated for the project of synchronizing the hydrogen masers based time scales by laser pulses. The technology demonstrator of a dual detector has been built and tested in our labs. The main parameters are: detection efficiency 10% at 532 nm, timing resolution 80 psec, dark count rate 8 kHz, non gated operation. The detectors active area is 25 um in diameter. The total mass, including bias stabilizing circuit, is 2 grams; the total power consumption is below 0.5 Wattper detecting channel.

Keywords

ltt

The result's identifiers

Alternative languages

  • Result language

    angličtina

  • Original language name

    Photon Counting Module for Laser Time Transfer Space Project

  • Original language description

    We are presenting the results of research and development of the Single Photon Avalanche Detector (SPAD) for application in a Laser Time Transfer (LTT) space mission. For this joint project with the Shanghai Observatory, Academy of Sciences of China, wehave developed a detector package dedicated for the project of synchronizing the hydrogen masers based time scales by laser pulses. The technology demonstrator of a dual detector has been built and tested in our labs. The main parameters are: detection efficiency 10% at 532 nm, timing resolution 80 psec, dark count rate 8 kHz, non gated operation. The detectors active area is 25 um in diameter. The total mass, including bias stabilizing circuit, is 2 grams; the total power consumption is below 0.5 Wattper detecting channel.

  • Czech name

  • Czech description

Classification

  • Type

    O - Miscellaneous

  • CEP classification

    BH - Optics, masers and lasers

  • OECD FORD branch

Result continuities

  • Project

  • Continuities

    Z - Vyzkumny zamer (s odkazem do CEZ)

Others

  • Publication year

    2008

  • Confidentiality

    S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů

Result type

O - Miscellaneous

O

CEP

BH - Optics, masers and lasers

Year of implementation

2008