Original language description
Accurate dose calculations are very important in radiotherapy treatment planning. The Monte Carlo method proved to be an accurate and reliable method for simulation of the dose distributions from electron beams and can provide more accurate distributionsthan conventional planning systems algorithms. The aim of the presented work was to assess the parameters and spectrum of given electron beam (Varian CLINAC 2100 C/D) from experimental depth dose distribution and simulate dose distributions in experimental arrangement with 3D polymer gel dosimeter. Comparison of experimental data, Monte Carlo calculations, and planning system enable to verify the used simulation model and technique as well as planning system results. Generation and influence of the bremsstrahlung photons in the electron beams was also analyzed using the simulation technique. The used computation and experimental method and acquired results are presented and discussed.
Czech name
—
Czech description
—
Classification
Type
J<sub>x</sub> - Unclassified - Peer-reviewed scientific article (Jimp, Jsc and Jost)
CEP classification
BG - Nuclear, atomic and molecular physics, accelerators
OECD FORD branch
—
Result continuities
Project
—
Continuities
Z - Vyzkumny zamer (s odkazem do CEZ)<br>S - Specificky vyzkum na vysokych skolach
Others
Publication year
2012
Confidentiality
S - Úplné a pravdivé údaje o projektu nepodléhají ochraně podle zvláštních právních předpisů
Data specific for result type
Name of the periodical
Radioprotection
ISSN
0033-8451
e-ISSN
—
Volume of the periodical
47
Issue of the periodical within the volume
1
Country of publishing house
FR - FRANCE
Number of pages
13
Pages from-to
79-91
UT code for WoS article
000303028700006
EID of the result in the Scopus database
—